{"id":5900,"date":"2026-11-16T10:47:05","date_gmt":"2026-11-16T09:47:05","guid":{"rendered":"https:\/\/web.infn.it\/TechTransfer\/?p=5900"},"modified":"2026-11-16T10:47:05","modified_gmt":"2026-11-16T09:47:05","slug":"infn-microdosimeters-to-study-hadron-therapy-beams","status":"publish","type":"post","link":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/","title":{"rendered":"INFN Microdosimeters to Study Hadron Therapy Beams"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n<h1 class=\"wp-block-heading\">The MIKRO and MUSICA detectors measure how radiation deposits energy on a microscopic scale<\/h1>\n\n<p class=\"wp-block-paragraph\">When it comes to advanced radiotherapy \u2013 such as hadron therapy with protons or carbon ions \u2013 the challenge is not only hitting the target, but doing so with maximum biological effectiveness while sparing the surrounding healthy tissue. To achieve this, however, it is not enough to know <strong><em>how much<\/em><\/strong> radiation is absorbed by the body as a whole: it is necessary to understand <strong><em>how<\/em><\/strong> that energy is deposited within a single cell, or even on a single chromosome.<\/p>\n\n<p class=\"wp-block-paragraph\">This is the frontier of <strong>microdosimetry<\/strong>, a field in which the INFN National Laboratories of Legnaro boast a tradition of excellence.<\/p>\n\n<h2 class=\"wp-block-heading\">Microdosimetry: why look at the micrometer scale<\/h2>\n\n<p class=\"wp-block-paragraph\">The same amount of water can fall as rain over a surface or be concentrated into a thin, high-pressure jet capable of even cutting through material. The same applies to radiation: the way energy is distributed in space and time can change its effect.<\/p>\n\n<p class=\"wp-block-paragraph\">Dose tells us how much energy is deposited on average per unit of mass. Microdosimetry helps us understand how this energy is distributed among microscopic volumes. For the same dose, the deposition can be more diffuse or more &#8220;granular,&#8221; with energy concentrated in small regions along the particle tracks. This difference helps explain why a beam of gamma rays and a beam of carbon ions can produce different biological effects even when delivering the same dose.<\/p>\n\n<p class=\"wp-block-paragraph\">Misurare direttamente gli effetti biologici delle radiazioni richiede esperimenti complessi e tempi lunghi. Per stimarli si ricorre a modelli che possono utilizzare i dati microdosimetrici. Ottenere questi dati nei centri di adroterapia richiede strumenti in grado di misurare nei fasci terapeutici e semplici da usare sul campo.<\/p>\n\n<h2 class=\"wp-block-heading\">MIKRO and MUSICA microdosimeters: innovation leaves the laboratory<\/h2>\n\n<p class=\"wp-block-paragraph\">To make these measurements more accessible, the research group led by Valeria Conte at the INFN National Laboratories of Legnaro has developed a new generation of tissue-equivalent proportional counters (TEPC). These detectors measure the energy deposited in a gas-filled cavity. The gas density is chosen so that the measurements represent the distribution of energy deposits in microscopic volumes of tissue. The data collected characterize the therapeutic beams and can be used in models that estimate their biological effects, with the aim of refining treatment planning.<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>MIKRO<\/strong>, developed as part of the <a href=\"https:\/\/web.infn.it\/TechTransfer\/en\/portfolio_page\/4mica\/\" data-type=\"portfolio_page\" data-id=\"693\">4MiCA<\/a> project, is a miniaturized microdosimeter designed to take measurements even in intense beams. Rugged and equipped with an interface that simplifies instrument control and data analysis, it is designed for direct use in hadron therapy centers.<\/li>\n\n\n\n<li><strong>MUSICA<\/strong>, developed by Anna Bianchi together with the research group, makes it possible to observe the same beam at different scales with a single detector. The innovation, <a href=\"https:\/\/web.infn.it\/TechTransfer\/en\/portfolio_page\/multi-site-tepc-type-particle-detector\/\">protected by an INFN patent<\/a>, consists of changing the size of the simulated tissue volume by adjusting the electric field inside the detector, while keeping the gas pressure constant. Studying how energy is deposited at different scales is important because radiation can damage structures such as chromosomes, whose dimensions are on the order of micrometers, and DNA, whose structure is observed at the nanometer scale.<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">A market-ready technology<\/h2>\n\n<p class=\"wp-block-paragraph\">MIKRO and MUSICA are not simple laboratory prototypes, but instruments already engineered to be reliable and easy to use even outside research centers. INFN&#8217;s current goal is to establish an <strong>industrial partnership<\/strong> to move from small-scale production to a commercial product ready for international clinical centers.<\/p>\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The MIKRO and MUSICA detectors measure how radiation deposits energy on a microscopic scale When it comes to advanced radiotherapy \u2013 such as hadron therapy with protons or carbon ions \u2013 the challenge is not only hitting the target, but doing so with maximum biological&#8230;<\/p>\n","protected":false},"author":4,"featured_media":5902,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[207],"tags":[402,245],"class_list":["post-5900","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-from-lab-to-the-world","tag-dosimetry","tag-life-sciences"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>INFN Microdosimeters to Study Hadron Therapy Beams - TechTransfer INFN<\/title>\n<meta name=\"description\" content=\"MIKRO and MUSICA, two microdosimeters for measuring the energy deposited by radiation on a micrometric scale\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"INFN Microdosimeters to Study Hadron Therapy Beams - TechTransfer INFN\" \/>\n<meta property=\"og:description\" content=\"MIKRO and MUSICA, two microdosimeters for measuring the energy deposited by radiation on a micrometric scale\" \/>\n<meta property=\"og:url\" content=\"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/\" \/>\n<meta property=\"og:site_name\" content=\"TechTransfer INFN\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/IstitutoFisicaNucleare\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-16T09:47:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2026\/11\/immagine-in-evidenza-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Diego Tonini\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Diego Tonini\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/\"},\"author\":{\"name\":\"Diego Tonini\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/#\\\/schema\\\/person\\\/00b4391eec00d565f3a1d39921d81aa9\"},\"headline\":\"INFN Microdosimeters to Study Hadron Therapy Beams\",\"datePublished\":\"2026-11-16T09:47:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/\"},\"wordCount\":571,\"publisher\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/immagine-in-evidenza-2.jpg\",\"keywords\":[\"dosimetry\",\"life sciences\"],\"articleSection\":[\"From lab to the world\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/\",\"url\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/\",\"name\":\"INFN Microdosimeters to Study Hadron Therapy Beams - TechTransfer INFN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/immagine-in-evidenza-2.jpg\",\"datePublished\":\"2026-11-16T09:47:05+00:00\",\"description\":\"MIKRO and MUSICA, two microdosimeters for measuring the energy deposited by radiation on a micrometric scale\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/infn-microdosimeters-to-study-hadron-therapy-beams\\\/#primaryimage\",\"url\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/immagine-in-evidenza-2.jpg\",\"contentUrl\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/immagine-in-evidenza-2.jpg\",\"width\":700,\"height\":450,\"caption\":\"two TEPC microdosimeters on a table\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/\",\"name\":\"INFN Trasferimento Tecnologico\",\"description\":\"Trasferimento Tecnologico | Istituto Nazionale Fisica Nucleare\",\"publisher\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/#organization\",\"name\":\"INFN Trasferimento Tecnologico\",\"url\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/wp-content\\\/uploads\\\/2023\\\/06\\\/INFN_techTransfer_logo_testo-e1708364168877.jpg\",\"contentUrl\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/wp-content\\\/uploads\\\/2023\\\/06\\\/INFN_techTransfer_logo_testo-e1708364168877.jpg\",\"width\":624,\"height\":260,\"caption\":\"INFN Trasferimento Tecnologico\"},\"image\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/IstitutoFisicaNucleare\\\/\",\"https:\\\/\\\/www.instagram.com\\\/infn_insights\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/#\\\/schema\\\/person\\\/00b4391eec00d565f3a1d39921d81aa9\",\"name\":\"Diego Tonini\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b852ae18da0b889e31c80cff41b73e37a1b074dc5b136acc1999c593d201828f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b852ae18da0b889e31c80cff41b73e37a1b074dc5b136acc1999c593d201828f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b852ae18da0b889e31c80cff41b73e37a1b074dc5b136acc1999c593d201828f?s=96&d=mm&r=g\",\"caption\":\"Diego Tonini\"},\"url\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/en\\\/author\\\/diego\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"INFN Microdosimeters to Study Hadron Therapy Beams - TechTransfer INFN","description":"MIKRO and MUSICA, two microdosimeters for measuring the energy deposited by radiation on a micrometric scale","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/","og_locale":"en_US","og_type":"article","og_title":"INFN Microdosimeters to Study Hadron Therapy Beams - TechTransfer INFN","og_description":"MIKRO and MUSICA, two microdosimeters for measuring the energy deposited by radiation on a micrometric scale","og_url":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/","og_site_name":"TechTransfer INFN","article_publisher":"https:\/\/www.facebook.com\/IstitutoFisicaNucleare\/","article_published_time":"2026-11-16T09:47:05+00:00","og_image":[{"width":700,"height":450,"url":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2026\/11\/immagine-in-evidenza-2.jpg","type":"image\/jpeg"}],"author":"Diego Tonini","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Diego Tonini","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/#article","isPartOf":{"@id":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/"},"author":{"name":"Diego Tonini","@id":"https:\/\/web.infn.it\/TechTransfer\/en\/#\/schema\/person\/00b4391eec00d565f3a1d39921d81aa9"},"headline":"INFN Microdosimeters to Study Hadron Therapy Beams","datePublished":"2026-11-16T09:47:05+00:00","mainEntityOfPage":{"@id":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/"},"wordCount":571,"publisher":{"@id":"https:\/\/web.infn.it\/TechTransfer\/en\/#organization"},"image":{"@id":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/#primaryimage"},"thumbnailUrl":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2026\/11\/immagine-in-evidenza-2.jpg","keywords":["dosimetry","life sciences"],"articleSection":["From lab to the world"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/","url":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/","name":"INFN Microdosimeters to Study Hadron Therapy Beams - TechTransfer INFN","isPartOf":{"@id":"https:\/\/web.infn.it\/TechTransfer\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/#primaryimage"},"image":{"@id":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/#primaryimage"},"thumbnailUrl":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2026\/11\/immagine-in-evidenza-2.jpg","datePublished":"2026-11-16T09:47:05+00:00","description":"MIKRO and MUSICA, two microdosimeters for measuring the energy deposited by radiation on a micrometric scale","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/web.infn.it\/TechTransfer\/en\/infn-microdosimeters-to-study-hadron-therapy-beams\/#primaryimage","url":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2026\/11\/immagine-in-evidenza-2.jpg","contentUrl":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2026\/11\/immagine-in-evidenza-2.jpg","width":700,"height":450,"caption":"two TEPC microdosimeters on a table"},{"@type":"WebSite","@id":"https:\/\/web.infn.it\/TechTransfer\/en\/#website","url":"https:\/\/web.infn.it\/TechTransfer\/en\/","name":"INFN Trasferimento Tecnologico","description":"Trasferimento Tecnologico | Istituto Nazionale Fisica Nucleare","publisher":{"@id":"https:\/\/web.infn.it\/TechTransfer\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/web.infn.it\/TechTransfer\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/web.infn.it\/TechTransfer\/en\/#organization","name":"INFN Trasferimento Tecnologico","url":"https:\/\/web.infn.it\/TechTransfer\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/web.infn.it\/TechTransfer\/en\/#\/schema\/logo\/image\/","url":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2023\/06\/INFN_techTransfer_logo_testo-e1708364168877.jpg","contentUrl":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2023\/06\/INFN_techTransfer_logo_testo-e1708364168877.jpg","width":624,"height":260,"caption":"INFN Trasferimento Tecnologico"},"image":{"@id":"https:\/\/web.infn.it\/TechTransfer\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/IstitutoFisicaNucleare\/","https:\/\/www.instagram.com\/infn_insights\/"]},{"@type":"Person","@id":"https:\/\/web.infn.it\/TechTransfer\/en\/#\/schema\/person\/00b4391eec00d565f3a1d39921d81aa9","name":"Diego Tonini","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/b852ae18da0b889e31c80cff41b73e37a1b074dc5b136acc1999c593d201828f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b852ae18da0b889e31c80cff41b73e37a1b074dc5b136acc1999c593d201828f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b852ae18da0b889e31c80cff41b73e37a1b074dc5b136acc1999c593d201828f?s=96&d=mm&r=g","caption":"Diego Tonini"},"url":"https:\/\/web.infn.it\/TechTransfer\/en\/author\/diego\/"}]}},"_links":{"self":[{"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/posts\/5900","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/comments?post=5900"}],"version-history":[{"count":2,"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/posts\/5900\/revisions"}],"predecessor-version":[{"id":5906,"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/posts\/5900\/revisions\/5906"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/media\/5902"}],"wp:attachment":[{"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/media?parent=5900"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/categories?post=5900"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/en\/wp-json\/wp\/v2\/tags?post=5900"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}