{"id":3055,"date":"2025-03-28T09:37:40","date_gmt":"2025-03-28T08:37:40","guid":{"rendered":"https:\/\/web.infn.it\/TechTransfer\/?post_type=portfolio_page&#038;p=3055"},"modified":"2025-03-28T09:37:40","modified_gmt":"2025-03-28T08:37:40","slug":"scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x","status":"publish","type":"portfolio_page","link":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/","title":{"rendered":"Scanner per Tomografia Computerizzata a fascio conico di raggi X"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column][vc_raw_html]JTVCd3BzZW9fYnJlYWRjcnVtYiU1RA==[\/vc_raw_html][vc_empty_space][vc_column_text]<\/p>\n<h1>Scanner per Tomografia Computerizzata a fascio conico di raggi X<\/h1>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column width=&#8221;2\/3&#8243;][vc_empty_space][vc_column_text]<span class=\"TextRun SCXW150325996 BCX0\" lang=\"IT-IT\" xml:lang=\"IT-IT\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW150325996 BCX0\">La presente invenzione riguarda uno scanner per Tomografia Computerizzata a fascio conico di raggi X (CBCT) con configurazione a sorgente multipla, progettato per migliorare le valutazioni quantitative.<\/span><\/span><span class=\"EOP SCXW150325996 BCX0\" data-ccp-props=\"{}\">\u00a0<\/span>[\/vc_column_text][vc_empty_space][vc_single_image image=&#8221;3056&#8243; img_size=&#8221;full&#8221; qode_css_animation=&#8221;&#8221;][vc_empty_space][vc_column_text]<\/p>\n<h3><span style=\"color: #20415c;\">Come funziona?<\/span><\/h3>\n<p>[\/vc_column_text][vc_empty_space][vc_column_text]<span data-contrast=\"auto\">La tecnologia CBCT permette di ottenere immagini tridimensionali della struttura interna di un soggetto attraverso la raccolta di proiezioni radiografiche acquisite da diverse angolazioni. Tuttavia questa tecnica presenta alcune limitazioni intrinseche che riducono l&#8217;accuratezza e la qualit\u00e0 delle ricostruzioni.\u00a0<\/span><span data-ccp-props=\"{&quot;335559739&quot;:0}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Oggetto della presente invenzione \u00e8 uno scanner per la tomografia a fascio conico con sorgenti multiple per studi di tipo quantitativi (qCBCT). L\u2019obiettivo \u00e8 quello di superare i limiti e migliorare la tecnologia della CBCT, rendendola pi\u00f9 adatta anche alle <\/span>valutazioni quantitative<span data-contrast=\"auto\">, cio\u00e8 quelle che richiedono misurazioni precise e affidabili.<\/span>[\/vc_column_text][vc_empty_space][vc_column_text]<\/p>\n<h3><span style=\"color: #20415c;\">Applicazioni<\/span><\/h3>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<ul>\n<li><span class=\"TextRun SCXW248873896 BCX0\" lang=\"IT-IT\" xml:lang=\"IT-IT\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW248873896 BCX0\">Oltre alle applicazioni in ambito medico, si prospetta un beneficio legato all\u2019uso anche in analisi e controlli di qualit\u00e0 di prodotti industriale.<\/span><\/span><span class=\"EOP SCXW248873896 BCX0\" data-ccp-props=\"{&quot;335559739&quot;:0}\">\u00a0<\/span><\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_empty_space][vc_column_text]<\/p>\n<h3><span style=\"color: #20415c;\">Vantaggi<\/span><\/h3>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<ul>\n<li>Miglioramento qualit\u00e0 immagine;<\/li>\n<li>Visibilit\u00e0 lesioni a basso contrasto;<\/li>\n<li>Riduzione artefatti;<\/li>\n<li>Estensione FOV utile;<\/li>\n<li>Applicazioni cliniche avanzate;<\/li>\n<li>Costo contenuto.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/4&#8243; css=&#8221;.vc_custom_1702567488600{margin-bottom: 50px !important;background-color: #042a48 !important;}&#8221; el_class=&#8221;.column_details_portfolio&#8221;][vc_column_text]<\/p>\n<h4><span style=\"color: #ffffff;\">DETTAGLI AGGIUNTIVI<\/span><\/h4>\n<p>[\/vc_column_text][vc_empty_space][vc_column_text]<\/p>\n<h5><span style=\"color: #8bc9e0;\"><strong>PROPRIETARI DEL BREVETTO<\/strong><\/span><\/h5>\n<p style=\"color: #fff; font-weight: bold;\">INFN<\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;21px&#8221;][vc_column_text]<\/p>\n<h5><span style=\"color: #8bc9e0;\"><strong>NUMERO DI PRIORIT\u00c0<\/strong><\/span><\/h5>\n<p><strong><span style=\"color: #ffffff;\">IT 102024000015823 <\/span><\/strong>[\/vc_column_text][vc_empty_space height=&#8221;21px&#8221;][vc_column_text]<\/p>\n<h5><span style=\"color: #8bc9e0;\"><strong>SETTORE TECNOLOGICO<\/strong><\/span><\/h5>\n<p><strong><span style=\"color: #ffffff;\">Diagnostica per immagini<\/span><\/strong>[\/vc_column_text][vc_empty_space height=&#8221;21px&#8221;][vc_column_text]<\/p>\n<h5><span style=\"color: #8bc9e0;\"><strong>CODICE TT<\/strong><\/span><\/h5>\n<p><strong><span style=\"color: #ffffff;\">P_24.017<\/span><\/strong>[\/vc_column_text][vc_empty_space][vc_row_inner row_type=&#8221;row&#8221; type=&#8221;full_width&#8221; text_align=&#8221;left&#8221; css_animation=&#8221;&#8221;][vc_column_inner el_class=&#8221;riga_spazio_progetti&#8221;][\/vc_column_inner][\/vc_row_inner][vc_empty_space][vc_column_text]<\/p>\n<h5><span style=\"color: #8bc9e0;\"><strong>CONTATTACI<\/strong><\/span><\/h5>\n<p><strong><span style=\"color: #ffffff;\">Per maggiori informazioni su questa tecnologia, <\/span><a href=\"mailto:tto@lists.infn.it\"><span style=\"text-decoration: underline;\"><strong><span style=\"color: #ffffff; text-decoration: underline;\">SCRIVICI<\/span><\/strong><\/span><\/a><\/strong>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column][vc_empty_space height=&#8221;51px&#8221;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column][vc_raw_html]JTVCd3BzZW9fYnJlYWRjcnVtYiU1RA==[\/vc_raw_html][vc_empty_space][vc_column_text] Scanner per Tomografia Computerizzata a fascio conico di raggi X [\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column width=&#8221;2\/3&#8243;][vc_empty_space][vc_column_text]La presente invenzione riguarda uno scanner per Tomografia Computerizzata a fascio conico di raggi X (CBCT) con configurazione a&#8230;<\/p>\n","protected":false},"author":6,"featured_media":3056,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","portfolio_category":[70,129,128],"portfolio_tag":[],"class_list":["post-3055","portfolio_page","type-portfolio_page","status-publish","has-post-thumbnail","hentry","portfolio_category-brevetti","portfolio_category-diagnostica-immagini-brevetti","portfolio_category-scienze-della-vita-brevetti"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Scanner per Tomografia Computerizzata a fascio conico di raggi X - TechTransfer INFN<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Scanner per Tomografia Computerizzata a fascio conico di raggi X - TechTransfer INFN\" \/>\n<meta property=\"og:description\" content=\"[vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column][vc_raw_html]JTVCd3BzZW9fYnJlYWRjcnVtYiU1RA==[\/vc_raw_html][vc_empty_space][vc_column_text] Scanner per Tomografia Computerizzata a fascio conico di raggi X [\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column width=&#8221;2\/3&#8243;][vc_empty_space][vc_column_text]La presente invenzione riguarda uno scanner per Tomografia Computerizzata a fascio conico di raggi X (CBCT) con configurazione a...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/\" \/>\n<meta property=\"og:site_name\" content=\"TechTransfer INFN\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/IstitutoFisicaNucleare\/\" \/>\n<meta property=\"og:image\" content=\"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2025\/03\/P_24.017.png\" \/>\n\t<meta property=\"og:image:width\" content=\"426\" \/>\n\t<meta property=\"og:image:height\" content=\"582\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/portfolio_page\\\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\\\/\",\"url\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/portfolio_page\\\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\\\/\",\"name\":\"Scanner per Tomografia Computerizzata a fascio conico di raggi X - TechTransfer INFN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/portfolio_page\\\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/portfolio_page\\\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/P_24.017.png\",\"datePublished\":\"2025-03-28T08:37:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/portfolio_page\\\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/portfolio_page\\\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/portfolio_page\\\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\\\/#primaryimage\",\"url\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/P_24.017.png\",\"contentUrl\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/P_24.017.png\",\"width\":426,\"height\":582},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/portfolio_page\\\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Brevetti\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/#website\",\"url\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/\",\"name\":\"INFN Trasferimento Tecnologico\",\"description\":\"Trasferimento Tecnologico | Istituto Nazionale Fisica Nucleare\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/web.infn.it\\\/TechTransfer\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Scanner per Tomografia Computerizzata a fascio conico di raggi X - TechTransfer INFN","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/","og_locale":"it_IT","og_type":"article","og_title":"Scanner per Tomografia Computerizzata a fascio conico di raggi X - TechTransfer INFN","og_description":"[vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column][vc_raw_html]JTVCd3BzZW9fYnJlYWRjcnVtYiU1RA==[\/vc_raw_html][vc_empty_space][vc_column_text] Scanner per Tomografia Computerizzata a fascio conico di raggi X [\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column width=&#8221;2\/3&#8243;][vc_empty_space][vc_column_text]La presente invenzione riguarda uno scanner per Tomografia Computerizzata a fascio conico di raggi X (CBCT) con configurazione a...","og_url":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/","og_site_name":"TechTransfer INFN","article_publisher":"https:\/\/www.facebook.com\/IstitutoFisicaNucleare\/","og_image":[{"width":426,"height":582,"url":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2025\/03\/P_24.017.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"2 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/","url":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/","name":"Scanner per Tomografia Computerizzata a fascio conico di raggi X - TechTransfer INFN","isPartOf":{"@id":"https:\/\/web.infn.it\/TechTransfer\/#website"},"primaryImageOfPage":{"@id":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/#primaryimage"},"image":{"@id":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/#primaryimage"},"thumbnailUrl":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2025\/03\/P_24.017.png","datePublished":"2025-03-28T08:37:40+00:00","breadcrumb":{"@id":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/#primaryimage","url":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2025\/03\/P_24.017.png","contentUrl":"https:\/\/web.infn.it\/TechTransfer\/wp-content\/uploads\/2025\/03\/P_24.017.png","width":426,"height":582},{"@type":"BreadcrumbList","@id":"https:\/\/web.infn.it\/TechTransfer\/portfolio_page\/scanner-per-tomografia-computerizzata-a-fascio-conico-di-raggi-x\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/web.infn.it\/TechTransfer\/"},{"@type":"ListItem","position":2,"name":"Brevetti"}]},{"@type":"WebSite","@id":"https:\/\/web.infn.it\/TechTransfer\/#website","url":"https:\/\/web.infn.it\/TechTransfer\/","name":"INFN Trasferimento Tecnologico","description":"Trasferimento Tecnologico | Istituto Nazionale Fisica Nucleare","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/web.infn.it\/TechTransfer\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"}]}},"_links":{"self":[{"href":"https:\/\/web.infn.it\/TechTransfer\/wp-json\/wp\/v2\/portfolio_page\/3055","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/web.infn.it\/TechTransfer\/wp-json\/wp\/v2\/portfolio_page"}],"about":[{"href":"https:\/\/web.infn.it\/TechTransfer\/wp-json\/wp\/v2\/types\/portfolio_page"}],"author":[{"embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/wp-json\/wp\/v2\/comments?post=3055"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/wp-json\/wp\/v2\/media\/3056"}],"wp:attachment":[{"href":"https:\/\/web.infn.it\/TechTransfer\/wp-json\/wp\/v2\/media?parent=3055"}],"wp:term":[{"taxonomy":"portfolio_category","embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/wp-json\/wp\/v2\/portfolio_category?post=3055"},{"taxonomy":"portfolio_tag","embeddable":true,"href":"https:\/\/web.infn.it\/TechTransfer\/wp-json\/wp\/v2\/portfolio_tag?post=3055"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}