UCLouvain
How to Apply Reimbursement Contact
CRC: Centre de Recherche du Cyclotron
Located in Louvain-la-Neuve (Belgium)20 km from Brussels airport. Cyclotron (K=110 MeV).One irradiation line for AIDA-2020 usersHIF: Heavy ion irradiation facility |
HIF: Heavy Ion irradiation facility
Installation build to measure the response of electronic components to single event effects.
Two heavy ions “cocktails” covering a wide range of LET and ranges, allowing to fully characterize SEE response of electronic components.
Cocktail No 1: High LET
M/Q | Ion | DUT energy [MeV] | Range [µm Si] | LET [MeV/mg/cm²] |
---|---|---|---|---|
5 | 40 Ar 8+ | 151 | 40 | 15.9 |
5 | 20 Ne 4+ | 78 | 45 | 6.4 |
5 | 15 N 3+ | 60 | 59 | 3.3 |
4.96 | 124 Xe 25+ | 420 | 37 | 67.7 |
4.94 | 84 Kr 17+ | 305 | 39 | 40.4 |
Cocktail No 2: High penetration
M/Q | Ion | DUT energy [MeV] | Range [µm Si] | LET [MeV/mg/cm²] |
---|---|---|---|---|
3.25 | 13 C 4+ | 131 | 292 | 1.1 |
3.14 | 22 Ne 7+ | 235 | 216 | 3 |
3.33 | 40 Ar 12+ | 372 | 117 | 10.2 |
3.22 | 58 Ni 18+ | 567 | 100 | 20.4 |
3.32 | 83 Kr 25+ | 756 | 92 | 32.6 |
3.54 | 124 Xe 35+ | 995 | 73.1 | 62.5 |
![]() | ![]() |
Both cocktails have close M/Q (~5 for the high LET and ~ 3.3 for the high penetration), allowing a fast ion changing within the same cocktail just modifying slightly the magnetic field and/or the RF. The beam flux is variable between a few particles/s.cm² and 1·104particles/s.cm². The beam flux can be modified from the user station; this is done with injection grids (for a constant attenuation factor) or by inflector bias variations (for intermediates values). The Homogeneity is ± 10 % on a 25 mm diameter.All irradiations are done in vacuum and for most of the ions naked chips are needed.
Please contact the beam line responsible person to obtain a detailed description of the mechanical constraints and the available feed-through.
Reimbursement Information
The claim form must be filled in and returned.
Travel costs for two people and hotel costs for one or two nights may be covered by AIDA-2020 for each project approved as well as the cost of shipping samples.
Contact
For further technical information please contact Eduardo Cortina.